An ongoing discussion is the influence of the torque of clamps. Earlier in this blog I found out that higher torque prevents cable connections from slipping.
Some people claim: Higher torque damages the cable. I wanted to check the effect on cyclic bending.
I took two pieces of 10 mm, 6 x 19 (fiber core) cable.
The load was a weight of 80 kg.
I applied a torque of 9 Nm to the first and 30 Nm to the second sample.
9 Nm is the torque stated by the Euronorm EN 13411-5, A. 30 Nm is at the yield point of the bail material.
I checked after 1000, 2000 and 3000 cycles under the clamp.
Here are the results:
Higher torque creates less wire breaks.
Interesting is that the breaking load was the same with both cables.
I tested a cable where I cut one strand (about 19 wires) with a grinder: 51 kN breaking load.
To check the change in the material I took a cable and loaded it with 1500 cycles, with 10 wires broken.
The breaking load was 29 kN.
I assume that the bending cyclic process damages a cable more than only the broken wires indicate.
Here is the overview: cyclic loaded aganist not loaded (grinded).
Conclusion:
The influence of torque in cyclic bending situations is low.
(Wire breaks occur later, but breaking load is similar).
Cyclic bending should be avoided if high loads are expected.